820-2936 dead

I had a short to GND on PP3V42_G3H and after I attached 3.4 Volts manually to that rail the short on that rail is gone. (without anything ****ing)

I think I have more shorts but one step after another

I have a short to GND on SMC_BC_ACOK too. I removed Q5310 and U6901.

R5078 is a Resistor to PP3V42_G3H and as I have no short there anymore it shouldn’t be the reason. My ISL ( U7000) was just freshly replaced and shouldn’t be the cause.